Freeze Dryer
PILOFD Series

  • Hits:217
  • Time:2024-4-7

Details

General Features

  • Whole process automatic operation - total automatic from pre-freeze, sublimation, secondary drying, end discrimination, stoppering, pressure recovery, defrosting to shutdown
  • Double protection design - if there is mis-operation, it will protect sample safety as well as machine safety.
  • Standard pilot freeze dryer - sample temperature ≤ -55 °C, cold trap temperature ≤75 °C, ultimate pressure≤1Pa
  • Modular pilot freeze dryer - Made of different modules depending on system configuration, much easier for maintenance and service
  • End discrimination - the program will enter end discrimination program automatically after secondary drying is completed, and enter next step after confirming sample is dried.
  • Sterile isolation design - the pilot freeze dryer can be placed standalone in lab or in clean room by through-wall mode, easy for use in multi-site
  • Vacuum control in whole process - control vacuum in different drying phases and realize automatic operation
  • Adjustable shelf spacing based on request - shelf spacing can be adjusted based on different sample height
  • Various of extensions - eutectic point measurement, computer remote control, dew point measurement


Parameters

Unit

PiloFD8-

4.3V

PiloFD8-

15.6V

PiloFD8-

2001V

PiloFD8-

4002V

PiloFD8-

5003V

Nominal Area

0.3

0.6

1

2

3

Capacity

Usable shelf area

0.24

0.54

0.05

2.16

3.24

Condenser capacity

Kg/B

4

10

15

35

50

Vial Qty.

Ф16mm

pcs

900

2200

4265

9070

13608

Vial Qty.

Ф22mm

pcs

460

1100

2268

4680

7020

Liquid capacity

L

4

10

15

35

50

Basic Parameter

Shelf

dimension

Width

mm

300

300

350

600

600

Length

mm

400

450

600

600

900

Shelf distance

mm

100

90

Shelf qty.

pcs

2+1

4+1

5+1

6+1

6+1

Shelf temp. range

-55~+80

Shelf temp. difference

±1(in balance)

Min. Cold trap temp.

≤-75

Vacuum leakage rate

Pam³/sec

≤5×10-3

Ultimate pressure

Pa

≤1

Basic Supply

Cooling type

Air-cooled,

well- ventilated

≤25

Water-cooled, ≤30°C,

0.15~0.2MPa

m³/hr

0..3

0.6

0.9

2

4

Installed power

Kw

3.3(single phase)

5(three phase)

8(three phase)

16(three phase)

21(three phase)

Total weight

Kg

510

820

1200

2000

2300

Dimension

Length

mm

700

900

1760

2200

2600

Width

mm

1300

1300

920

1400

1500

Height

mm

1700

1800

2200

2100

2400